Rectifier Chargers GR(B)
Rectifier Chargers GR (B)(TECNED)
From 0.1kW to 15kW
TECNED rectifier/chargers are based on Thyristor + Concept (SCR+IGBT) technology with a galvanic separation transformer, input PF 0.98, low input harmonics (<10%), standard low DC ripple (< 2% for 3-phase systems).
Like all GR-models, the GR(B)-series is short circuit proof, includes high DC protection as standard to protect the load and delivers a steady output voltage under al operating conditions.
Optional built-in batteries up to 9x 12V/100Ah for 110Vdc installations can provide back-up for small and medium installations. In combination with 12V/40AH and 12V/75AH batteries, up to 8 x 2P distributions MCB’s can be fitted for easy implementation.
The GR(B)-series is supplied in a floor standing sheet steel cabinet with bottom cable entry.
The GR(B) series is the basic charger available in the TECNED GR product family with limited options. It strictly adheres to a truly industrial design with convection cooling and is built for 20 years operational life-time.
The TECNED GR (B) Rectifier / Charger series is available from 24Vdc to 650Vdc nominal with up to 100A output in a single enclosure.
TECNED rectifier/chargers are based on Thyristor + Concept (SCR+IGBT) technology with a galvanic separation transformer, input PF 0.98, low input harmonics (<10%), standard low DC ripple (< 2% for 3-phase systems).
Like all GR-models, the GR(B)-series is short circuit proof, includes high DC protection as standard to protect the load and delivers a steady output voltage under al operating conditions.
Optional built-in batteries up to 9x 12V/100Ah for 110Vdc installations can provide back-up for small and medium installations. In combination with 12V/40AH and 12V/75AH batteries, up to 8 x 2P distributions MCB’s can be fitted for easy implementation.
The GR(B)-series is supplied in a floor standing sheet steel cabinet with bottom cable entry.
Features and Benefits
• High power factor IGBT/SCR conversion technology with very low input THDI and build-in galvanic separation transformer.
• Charging characteristic according DIN 41773 (UI)
• High reliable due to failsafe control system and protection circuits
Specifications
• Input voltage single phase: 110 / 120 / 200 / 220 / 230 / 240 / 277V, (2W+E)
• Input voltage three phase: 208 / 220 / 240 / 380 / 400 / 415 / 480V, (3W+E)
• Input voltage range: +15%/-20% (20% start battery operation)
• Nominal input frequency: 50/60 Hz
• Power factor: 0.98
• Efficiency: Up to 95% (depending on DC bus voltage)
• Nominal output voltage: 24, 48, 60, 110 (125), 380 Vdc
• Battery charging characteristic: IU (DIN 41773), T° compensated floating voltage
Sản phẩm cùng mục
Rectifier Chargers GR(B)
Rectifier Chargers GR (B)(TECNED)
From 0.1kW to 15kW
TECNED rectifier/chargers are based on Thyristor + Concept (SCR+IGBT) technology with a galvanic separation transformer, input PF 0.98, low input harmonics (<10%), standard low DC ripple (< 2% for 3-phase systems).
Like all GR-models, the GR(B)-series is short circuit proof, includes high DC protection as standard to protect the load and delivers a steady output voltage under al operating conditions.
Optional built-in batteries up to 9x 12V/100Ah for 110Vdc installations can provide back-up for small and medium installations. In combination with 12V/40AH and 12V/75AH batteries, up to 8 x 2P distributions MCB’s can be fitted for easy implementation.
The GR(B)-series is supplied in a floor standing sheet steel cabinet with bottom cable entry.
Rectifier Chargers GR(B) 19 inch
Rectifier Chargers GR(B) 19 inch (TECNED)
From 0.1kW to 50kW